SCIENTIFIC SECTOR CATALOGUE - Flipbook - Page 15
Spirit ASTM equivalent thermometers
The following thermometers have been developed (product references 55/---/-) as spirit 昀椀lled alternatives to the
standard mercury 昀椀lled ASTM thermometers. Those marked with an “S”, ie “S5C”, are exact equivalents to the
ASTM Standard and are manufactured to E2251-14 “Liquid-in Glass ASTM Thermometers with Low Hazard
Precision Liquids”, others are produced similar to the Standard. The thermometers marked * are spirit 昀椀lled
thermometers from the original ASTM series and are still available. A range of IP equivalent thermometers are
also being developed (product references 56/---/-).
All these thermometers can be supplied with UKAS (0582) calibration certi昀椀cate or statement of conformity.
Calibration needed?
See calibration section
of this catalogue
Equivalent
ASTM number
1C
Range
Partial Immersion
-20 to +150°C
1F
Partial Immersion
S5C
Cloud & Pour
-38 to
0 to +302°F
S5F
Cloud & Pour
6C
Low Cloud & Pour
6F
Low Cloud & Pour
7C
Divisions
Max
length
Immersion
Product
number
1.0°C
327mm
76mm
55/001/2
2.0°F
327mm
76mm
55/001/1
1.0°C
235mm
108mm
55/005/2
-36 to +120°F
2.0°F
235mm
108mm
55/005/1
-80 to
+20°C
1.0°C
235mm
76mm
55/006/2#
-112 to
+70°F
2.0°F
235mm
76mm
55/006/1#
Low Distillation
-2 to +300°C
1.0°C
290mm
Total
55/007/2##
7F
Low Distillation
+30 to +300°F
2.0°F
290mm
Total
55/007/1##
8C
High Distillation
-2 to +400°C
1.0°C
390mm
Total
55/008/2##
8F
High Distillation
+30 to +760°F
2.0°F
390mm
Total
55/008/1##
9C
Low Pensky-Martens
-5 to +110°C
0.5°C
295mm
57mm
55/009/2
+50°C
9F
Low Pensky-Martens
+20 to +230°F
1.0°F
295mm
57mm
55/009/1
11C
Cleveland Open Flash
-6 to +400°C
2.0°C
310mm
25mm
55/011/2##
S12C
Density Wide Range
-20 to +102°C
0.2°C
425mm
Total
55/012/2
S12F
Density Wide Range
-5 to +215°F
0.5°F
425mm
Total
55/012/1
13C
Loss on Heating
+155 to +170°C
0.5°C
160mm
Total
55/013/2
14C
Wax Melting Point
+38 to
0.1°C
380mm
79mm
55/014/2
+100 to +180°F
14F
Wax Melting Point
S15C
Low Softening Point
S15F
Low Softening Point
16C
High Softening Point
+82°C
0.2°F
380mm
79mm
55/014/1
0.2°C
400mm
Total
55/015/2
-30 to +180°F
0.5°F
400mm
Total
55/015/1
+30 to +200°C
0.5°C
400mm
Total
55/016/2
-2 to
+80°C
High Softening Point
+85 to +392°C
1.0°F
400mm
Total
55/016/1
Saybolt Viscosity
+19 to
0.1°C
280mm
Total
55/017/2
+27°C
17F
Saybolt Viscosity
+66 to
+80°F
0.2°F
280mm
Total
55/017/1
S18C
Reid Vapour Pressure
+34 to
+42°C
0.1°C
280mm
Total
55/018/2
S18F
Reid Vapour Pressure
+94 to +108°F
0.2°F
280mm
Total
55/018/1
19C
Saybolt Viscosity
+49 to
0.1°C
280mm
Total
55/019/2
+57°C
19F
Saybolt Viscosity
+120 to +134°F
0.2°F
280mm
Total
55/019/1
20C
Saybolt Viscosity
+57 to
0.1°C
280mm
Total
55/020/2
+65°C
20F
Saybolt Viscosity
+134 to +184°F
0.2°F
280mm
Total
55/020/1
21C
Saybolt Viscosity
+79 to
0.1°C
280mm
Total
55/021/2
+87°C
21F
Saybolt Viscosity
+174 to +188°F
0.2°F
280mm
Total
55/021/1
S22C
Oxidation Stability
+95 to +103°C
0.1°C
280mm
Total
55/022/2
S22F
Oxidation Stability
+204 to +218°F
0.2°F
280mm
Total
55/022/1
23C
Engler Viscosity
+18 to
+28°C
0.2°C
217mm
90mm
55/023/2
Engler Viscosity
+39 to
+54°C
0.2°C
242mm
90mm
55/024/2
Toluene 昀椀lled
#2
Measurement for life.
16F
17C
24C
#1
Name
Laboratory thermometers
Please ask our Sales Team for information regarding calibration of for other thermometers not listed below.
Gallium 昀椀lled
brannan.co.uk
sales@brannan.co.uk
15