PROCESS INSTRUMENTATION - Flipbook - Page 81
Cooling towers - ACT001 / ACT002
Comparison:
• ACT001 has much higher temperature reduction than ACT002.
• ACT001 can only be o昀昀ered in SS316/SS316L material. ACT002 can be o昀昀ered in various materials.
• ACT001 can be used for 昀氀uids that do not have contamination or particles and viscosity less than 500 CST
as the 昀氀ow path diameter is only 1.5mm, ACT002 can be used with any type of 昀氀uids, including with 昀氀uids
containing particles or contaminations.
Product numbers:
All ACT001 and ACT002 cooling towers are ordered to speci昀椀c customer speci昀椀cations. Please use below matrix to
create your unique ordering product reference, using the values in bold.
Model
Wetted material
Process/instruments
connection
Connection
size & type
Brannan
(BRN)
Perforated
type
(ACT001)
SS316
(316)
Male to Female
(MF)
1/4’’ x 1/4’’ BSP
(3)
Fin
type
(ACT002)
1/4’’ x 1/4’’ NPT
(4)
SS316L
(316L)
1/4’’ x 1/4’’ BSPT
(10)
Extras
Materials test
certi昀椀cate
(MTC)
Compliance to
NACE MR-0175
(NACE)
Accessories
Make
3/8’’ x 3/8’’ BSP
(5)
3/8’’ x 3/8’’ NPT
(6)
3/8’’ x 3/8’’ BSPT
(11)
1/2’’ x 1/2’’ BSP
(7)
1/2’’ x 1/2’’ NPT
(8)
1/2’’ x 1/2’’ BSPT
(12)
NB. When more than one
extra is required, please
separate each code with a
hyphen when building your
product reference
Order example:
Model
Wetted material
Process/instruments
connection
Connection
size & type
Extras
BRN
ACT001
316
MF
8
MTC
Product reference: BRNACT001/316/MF/8/MTC
brannan.co.uk
sales@brannan.co.uk
Measurement for life.
Make
81